A water heater thermocouple is a small safety sensor that keeps the gas valve open only while the pilot flame is lit. If the pilot lights and then goes out when you release the knob, the thermocouple is the first thing to suspect. Replacement is inexpensive, but the job involves gas, so many homeowners hire a plumber.
If you smell gas, leave the house and call the gas utility from outside. Do not relight a pilot in a gas smell. For a heater that will not stay lit, call and ask about timing.
Signs of a Failing Thermocouple
These symptoms usually point to the sensor.
- The pilot lights but dies when you release the knobThe sensor is not holding the valve open.
- No hot water after a pilot outageThe heater shut off for safety.
- A pilot flame that looks weak or yellowThe flame may not heat the sensor.
- A black or bent thermocouple tipThe metal is worn or misaligned.
- Repeated relightsThe sensor or the flame is inconsistent.
How the Replacement Works
This is the sequence a plumber follows.
Shut off gas and let the heater cool
The gas control is set to off.
Remove the burner assembly cover
The pilot assembly is exposed.
Unscrew the old thermocouple
It connects to the gas valve and sits in the pilot flame.
Install the new one
The tip is positioned in the flame and the nut is snug.
Relight and test
We check the flame, the gas connections and the draft.
No Hot Water?
Call (909) 505-3225 and ask about help to diagnose the pilot, the thermocouple and the gas control.
Call (909) 505-3225Pilot Problems Compared
The thermocouple is common, but not the only cause.
| Symptom | Likely cause | Fix |
|---|---|---|
| Pilot will not stay lit | Worn thermocouple | Replace the thermocouple. |
| Pilot will not light | Clogged pilot orifice | Clean the pilot. |
| Weak flame | Dirty burner or low gas pressure | Clean and check supply. |
| Pilot blows out | Draft or vent problem | Check the vent and combustion air. |
Garage Heaters and Highland Guidance
The City of Highland's April 2017 Water Heater Installation Bulletin lists an 18 inch elevation for the ignition source of a heater in a garage, along with combustion air, venting, strapping and a drain pan. A pilot flame is an ignition source, so a heater sitting on the floor of a garage may need a platform. The bulletin does not address permits. Ask Building and Safety at 27215 Baseline.
Relighting is not the right fix if the heater has a venting problem. A draft that blows out the pilot can mean a blocked vent. That is a safety issue, and a plumber can check it. See water heater repair.
Replacement parts should match the manufacturer's specifications for your model, according to the heater's manual, and gas connections follow the plumbing and fuel gas rules the state adopts.
Safe Steps If the Pilot Goes Out
Do these before you decide on a repair.
Smell for gas
If you smell gas, leave the home and call the gas utility from outside.
Check the gas valve and the breaker
Confirm the gas control is on and the room is ventilated.
Follow the label to relight
Use the instructions on the heater.
Watch the flame
A steady blue flame is normal. A weak or yellow flame is not.
Call a plumber if it fails twice
Repeated outages mean a part or a vent is failing.
Why the Heater Is Not Just a Pilot Problem
A heater that loses its pilot often has another issue behind it. A blocked flue, poor combustion air or sediment in the tank can all cause trouble. A new thermocouple will not fix those causes.
A plumber checks the vent draft, the burner and the tank condition while the part is replaced. That check is what protects you from carbon monoxide, which cannot be seen or smelled.
When a Thermocouple Is Not Enough
If the heater is more than ten years old, rusted at the base or damp around the tank, replacing the thermocouple may only buy a short delay. A leaking tank cannot be repaired. Ask your plumber to judge the whole heater and not only the part.
A new heater also gives you better efficiency and a current safety design, which matters in a garage with an ignition source.
Carbon Monoxide Awareness
Gas heaters produce carbon monoxide as a byproduct. A properly vented heater sends it outside. A blocked vent, a damaged flue or a draft problem can send it into the home. A working carbon monoxide alarm near the sleeping area is a simple protection.
If your alarm sounds, leave the home, call emergency services and do not go back until the source is found. After any heater repair, test the alarm and keep its batteries fresh.
Repair or Replace
A thermocouple is a cheap part, and replacing it is worth it on a heater in good condition. If the tank is leaking, rusting at the base or more than a decade old, replacement is a better use of money.
See water heater replacement for the options. We serve Redlands and San Bernardino as well as Highland.
Frequently Asked Questions
It involves a gas connection, so a plumber is the safer choice. Never work on a gas line if you smell gas.
A worn thermocouple is the common cause. A draft or a dirty pilot can also blow it out.
Many newer units use electronic ignition and flame sensors instead of a pilot.
The April 2017 bulletin lists an 18 inch elevation for ignition sources in garages.